Sensitivity and accuracy enhanced by minimizing the reagent blanks that hinder accurate analysis.
Powerful oxidation through a combination of peroxosulfuric acid, UV illumination, and heating.
No need of purging of reagent bottle reduces consumption of carrier gas
Measurement Principle
TC Measurement
IC Measurement
TOC Measurement
NPOC Measurement
Features of S model


The method function registers measurement conditions.
Features
When creating the calibration curve, the optimal measurement conditions are displayed when the standard solution concentration is set. Detailed calibration curve information can easily be referenced when setting the measurement conditions.
Automatic condition changing and re-analysis of out-of-range samples
If the sample peak goes over the calibration curve range, measurement conditions such as dilution rate and injection volume are automatically changed and the analysis is repeated.
Automatic selection of the best calibration curve
Up to three calibration curves can be set for sample measurement. The optimal calibration curve is selected for the sample and the sample measurements are conducted using these measurement conditions.
Automatic exclusion of anomalous values and re-calculation of repeated analyses
The mean value, standard deviation, and coefficient of variation are displayed and printed during repeated analyses. Anomalous values can be automatically eliminated and re-calculated.
Convenient automatic power off function
Automatic power off after electric furnance cools down ensures power is not left on and saves energy.
Comprehensive calibration system handles many uses
- Calibration curve can be created to compensate for TC in water used for standard solution adjustment.
- A maximum of 25 (model S. model P has no limit) calibration curves can be stored and recalled. All calibration curve data can be displayed and recorded.
Features of P model
Wizards allow simple input of measurement and calibration settings.

Comprehensive security functions such as password input and operator access restrictions.

The measurement conditions and results can be output to EXCEL or other application software or input from other application software.
Features
Automatic setting of optimal measurement conditions
Detailed calibration curve information can easily be referenced when setting the measurement conditions.
Automatic condition changing and re-analysis of out-of-range samples
Automatic selection of the best calibration curve
Automatic exclusion of anomalous values and re-calculation of repeated analyses
Anomalous values can be automatically eliminated and re-calculated.
Convenient automatic power off function
Comprehensive calibration system handles many uses
- Calibration curve can be created to compensate for TC in water used for standard solution adjustment.
- A maximum of 25 (model S. model P has no limit) calibration curves can be stored and recalled. All calibration curve data can be displayed and recorded.
PC specification required
CPU | 233MHz or more |
---|---|
Memory | 32M or more |
HDD | 2G or more |
OS | Windows 95, Windows 98, Windows 2000, Windows Me, Windows NT4.0 (SP3 or after) |
Monitor resolution | 800 x 600 or more, 1024 x 768 (recommended) |