The SEC FLUV chambers utilize a combination of UVA and UVB lamps to perform UV conditioning. Mounted on three racks, these instruments can accommodate up to six full PV modules. The smaller chamber, SEC 3300 FLUV, fits up to six PV modules with a size of 1.0 x 1.6 m. The larger type SEC 6000 FLUV can accommodate six 1.6 x 2.0 m PV modules.
In addition, the SEC FLUV chambers are able to perform the Damp Heat Test according to the IEC standards.
FEATURES
- SEC 3300 Fluorescent UV Light Source Component
Lamp: UV 351 (UVA) + UV 313 (UVB)
Type: Fluorescent Type
Number of lamps: 40 W (36 UVA+36 UVB)
Test PV Module Size: 1000 x 1600 mm (For testing of 6 Modules)
Wavelength: 280 ~ 400 nm - SEC 6000 Fluorescent UV Light Source Component
Lamp: UV 360 (UVA) + UV 310 (UVB)
Type: Fluorescent Type
Number of lamps: 100 W (42 UVA+42 UVB)
Test PV Module Size: 1600 x 2000 mm (For testing of 6 Modules)
Wavelength: 280 ~ 400 nm - Environmental Chamber Component
- Physical Dimensions SEC 3300 FLUV
Test chamber capacity approx. 3300 L
Internal: 1300W x 1350D x 1900H mm
External: 1850W x 2800D x 2640H mm - Physical Dimensions SEC 6000 FLUV
Test chamber capacity approx. 6000 L
Internal: 1300W x 2100D x 2250H mm
External: 1,850W x 3310D x 2793H mm - Temperature
Temperature Range: 0°C ~ +90°C
Temperature Accuracy: ±1°C
Temperature Uniformity: ±2°C
Ramping Rate – Cool Down: 0.5°C/min
Ramping Rate – Heat Up: 0.5°C/min - Humidity
Humidity Range: 30% ~ 95% RH
Humidity Accuracy: ±5% - Other Chamber Characteristics
Condensing Type: Water Cooled Type
Coolant: CFC Free R-404A, R-23
Added Capabilities: 85°C, 85% capable (IEC Damp Heat Test) - Main Instrumentation Features
- Chamber Control
Fully integrated FL UV light and environmental control
12.1" color touch screen Graphic User Interface
Intuitive control features and easy-to-use programming logic
Built-in industrial computer with full MS Windows functionality - Measurement
6 Channel DAQ integrated for temperature sensors
Multi-source temperature control pre-implemented and selectable in user interface
Pre-wired for plug-and-play XenoCal Solar for irradiance measurement - Design
Galvanized steel with powder coated exterior
Robust refrigeration system for precision control of environmental parameters
Multi-stage safety features
CE certified - Electrical Voltage: 400 V ±10% (3, N, PE) AC, 50/60 Hz
Other voltages available upon request.
STANDARDS
- IEC 61215
Crystalline silicon terrestrial photovoltaic (PV) modules – Design qualification and type approval