Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
Cable fault locator
The fault locator ISOPALM 200 is designed to identify and locate with high precision any faults on telecom cables: insulation faults (bare, blasted, buried wires) and break on wires (partial or total break).
- Display of fault location in meters
- Suitable for Pupin coils
- Homogeneous and heterogeneous cables
Instrument:
ISOPALM 200 Cable fault locator
Delivered in standard with:
- Remote looping device
- Set of testing leads and crocodile clips
- User manual
- Transport case, shoulder strap and stand
Packing information:
Size 210 x 110 x 50 mm
Weight 900 g
Measurement of AC / DC voltage
Range | Resolution | Accuracy / 1 year |
-300 to 300 V AC / DC | Up to 99.9 V: 0.1 V From 100 to 300 V: 1 V |
±1% RDG + 0.5 V |
Resistance measurement
Range | Resolution | Accuracy / 1 year |
0 to 10 KΩ | Up to 1000 Ω: 0.1 Ω Beyond 1000 Ω: 1 Ω |
±0.5% RDG + 0,2 Ω |
Isolation measurement at test voltage 50 to 100 V
Range | Resolution | Accuracy / 1 year |
0 to 10 KΩ | Up to 1000 Ω: 0.1 Ω Beyond 1000 Ω: 1 Ω |
±0.5% RDG + 0.2 Ω |
Isolation measurement at test voltage 150 to 300 V
Range | Resolution | Accuracy / 1 year |
0 to 5000 MΩ | From 0 to 999 kΩ: 2 digits after coma From 1 MΩ to 9.99 MΩ: 2 digits after coma From 10 MΩ to 99.9 MΩ: 1 digit after coma From 100 MΩ to 5 GΩ: 0 digit after coma |
From 1 MΩ to 999 MΩ: ±10% RDG Beyond: ±10% RDG + 30 kΩ |
Isolation measurement at test voltage 350 to 500 V
Range | Resolution | Accuracy / 1 year |
0 to 10000 MΩ | From 0 to 999 kΩ: 2 digits after coma From 1 MΩ to 9.99 MΩ: 2 digits after coma From 10 MΩ to 99.9 MΩ: 1 digit after coma From 100 MΩ to 10 GΩ: 0 digit after coma |
From 1 MΩ to 999 MΩ: ±10% RDG Beyond: ±10% RDG + 30 kΩ |
Capacitance measurement
Range | Resolution | Accuracy / 1 year |
0 nF to 2 µF | From 0 nF to 1000 nF: 1 nF From 1000 nF to 2000 nF: 2 nF |
±1% RDG |
Fault location
Type | Accuracy / 1 year |
Fault between 2 wires on the same pair Fault between 2 wires on different pairs Fault between 1 wire and the ground |
±1% RDG |
Fault location methods integrated into the instrument
Method | Principle |
Sauty | Location of broken wire: With measurement of loop resistance, if Rab > 10 000 Ω, the wire is broken Test on homogeneous cables |
Murray | Location of insulation fault: If Ihealthy > 1000, Iunhealthy (ou Ib > 1000 Ia) Test on homogeneous and heterogeneous cables |
Fabe / Küpfmüller | Location of insulation fault: If Ihealthy/ Iunhealthy > 2 x Rhealthy/Runhealthy, Ih+Iu > 1000 Rab, Ihealthy and Iunhealthy Test on homogeneous and heterogeneous cables |
General specifications
Size | 210 x 110 x 50 mm |
Weight | 900 g |
Display | 240 x 320 pixel liquid crystal graphical display with backlite and contrast control |
Power supply | 230 V ±10 %, 50/60 Hz |
Battery | Type: Li/Ion Charging time: 4 h Lifetime: 10 h |
Environmental specifications
Reference range | 23°C ±5°C (RH: 45 to 75 % w/o condensing) |
Operating reference range | -10 to 50°C (RH: 20 to 80 % w/o condensing) |
Limit operating range | -15°C to +55°C (RH: 10 to 80 % w/o condensing) (70% at 55°C) |
Storage temperature limits | -30°C to +60°C |
Maximum height | 0 to 2000 m |
IP protection | IP54 according to EN60529 |
Safety specifications
Class | In accordance with EN 61010-1 Category II, pollution 2 |
Chocks and vibrations | EN 61010-1 |
EMC conformity | Immunity:
EN 61000-4-4
|
Resource & Download
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@vnation.com.vn | Sales: +84 0939021319 | AOIP-Cable fault locator (Model: ISOPALM 200).